The device Hydrocont HP4 is an electronic hydrostatic filling level transmitter for monitoring, control and continuous measurement of filling levels and temperatures.Due to its high accuracy and the digital adjustability by RS485 Modbus®-RTU the Hydrocont HP4 can be suited to a wide variety of applications. The robust design and the high quality workmanship turns the device into a very high quality product, which even the most adverse environmental conditions cannot affect, whether the lowest temperatures when used outdoors, extreme shock and vibration stress or aggressive media.

A captive laser marking of the type label ensures the identifiability throughout the entire lifetime of the device. Obviously is the optional marking of a measurement point designation resp. TAG, a customer label or of a neutral type label, of course also per laser marking. A LABS- resp. silicone-free version, a factory calibration with calibration certificate and a customer specific configuration resp. preset is also optionally available like a material test certificate EN10204 3.1 or a factory certifications for drink water suitability. Customer specific special versions can be realized short-term on request, e.g. special designs or other process materials.

Nom. pressure PN relative 0...+0,1 bar up to 0...+10 bar
Characteristic deviation ≤ ±0,05% FSO; ≤ ±0,1% FSO; ≤ ±0,2% FSO
Temperature deviation Tk Zero ≤ ±0,015% FSO/K
Time behavior T90 ≤ 2ms (td = 0s)
Sensor type Pt1000 Class A
Characteristic deviation ≤ ±0,1K + 0,002 x [dt (25°C)]
Time behavior T90 ≤ 4s
Interface RS485, bidirectional, Modbus-RTU, 9600 Baud
Time behavior ton ≤ 250ms (td = 0s)
Supply voltage Us (polarity protected) 6 V ... 35 V DC
Coarse protection 75 V / 10kA – wave 8/20µs all lines to PE
Fine protection 36V all lines to -L
Environmental temperature -20°C ... +70°C
Protection class IP68 (EN/IEC 60529)
Materials (Process wetted) Ceramic Al2O3, CrNi-Steel, FPM, EPDM, PE, PUR

Examples of supplied versions: expand / close

Hydrocont HP4 SCS01V001V00RKA Hydrocont HP4 SCS03V001V00RKA
Hydrocont HP4 SCS01D001V00RKA Hydrocont HP4 SCS03D001V00RKA
Hydrocont HP4 SCS01V005V00RKA Hydrocont HP4 SCS03V005V00RKA
Hydrocont HP4 SCS01D005V00RKA Hydrocont HP4 SCS03D005V00RKA
Hydrocont HP4 SCS01V010V00RKA Hydrocont HP4 SCS03V010V00RKA
Hydrocont HP4 SCS01D010V00RKA Hydrocont HP4 SCS03D010V00RKA
Hydrocont HP4 SCS01V012V00RKA Hydrocont HP4 SCS03V012V00RKA
Hydrocont HP4 SCS01D012V00RKA Hydrocont HP4 SCS03D012V00RKA
Hydrocont HP4 SCS01V001V10RKA Hydrocont HP4 SCS03V001V10RKA
Hydrocont HP4 SCS01D001V10RKA Hydrocont HP4 SCS03D001V10RKA
Hydrocont HP4 SCS01V005V10RKA Hydrocont HP4 SCS03V005V10RKA
Hydrocont HP4 SCS01D005V10RKA Hydrocont HP4 SCS03D005V10RKA
Hydrocont HP4 SCS01V010V10RKA Hydrocont HP4 SCS03V010V10RKA
Hydrocont HP4 SCS01D010V10RKA Hydrocont HP4 SCS03D010V10RKA
Hydrocont HP4 SCS01V012V10RKA Hydrocont HP4 SCS03V012V10RKA
Hydrocont HP4 SCS01D012V10RKA Hydrocont HP4 SCS03D012V10RKA
Hydrocont HP4 SCS01V001V30RKA Hydrocont HP4 SCS03V001V30RKA
Hydrocont HP4 SCS01D001V30RKA Hydrocont HP4 SCS03D001V30RKA
Hydrocont HP4 SCS01V005V30RKA Hydrocont HP4 SCS03V005V30RKA
Hydrocont HP4 SCS01D005V30RKA Hydrocont HP4 SCS03D005V30RKA
Hydrocont HP4 SCS01V010V30RKA Hydrocont HP4 SCS03V010V30RKA
Hydrocont HP4 SCS01D010V30RKA Hydrocont HP4 SCS03D010V30RKA
Hydrocont HP4 SCS01V012V30RKA Hydrocont HP4 SCS03V012V30RKA
Hydrocont HP4 SCS01D012V30RKA Hydrocont HP4 SCS03D012V30RKA