The differential pressure manometer DA10 serves to measure and display differential pressures in gaseous, fluid and aggressive media. The unit is completely made of CrNi-steel and is suitable for use in aggressive environments. The measuring system differs because it uses CrNi steel and/or Hastelloy. The differential pressure that is to be measured acts on the separating dia-phragms and is transferred hydraulicaly onto the measuring diaphragm. Whenthe pressure is equalised, this is in its idle state. In case of pressure difference,the force acting on the measuring membrane causes it to be moved towards theside of the lower pressure. The deflection is transferred to the display mechan-ism as a rotary movement via a toriosn tube. If the measuring system is loaded above the measuring range, the separatingdiaphragms are supported on parts of the system casing with the same con-tours. In this way, the measuring system is protected against overload.